Version 1.2.0 Current
2 new2 fixes
Added
- Design standard input: ACI 318-19 (default) or ACI 318-25. ACI 318-25 adds Cl 21.2.2.3: between 0.1f′c·Ag and Pn,bal, φ is limited to a linear interpolation from 0.90 to φcc (not applied when Pn,bal < 0.1f′c·Ag).
- Report: the standard in the title and inputs; for ACI 318-25, the φ limit and the φ used at each point.
Fixed
- Curve chart: the phi Pn,max label is no longer hidden behind the chart buttons when the nominal curve is off.
- Curve chart in Compare: the legend no longer overlaps the axis labels or curves. Sections A and B are listed below the Moment title, the nominal curves at the top left.
Results
- No changes to existing results. ACI 318-19 is unchanged, and saved models open as ACI 318-19.
- ACI 318-25: same nominal strengths; φPn and φMn can be lower between 0.1f′c·Ag and Pn,bal.